7
Installer S
ettings
Sum
mary
Setting
Range
Default
Display Lock
Y or N
N
Locks out front buttons
Service Mode Submenu
Test Mode
Y or N
N
Reduces delays for testing
System Settings Submenu
Mechanical Settings Submenu
Sys
Type
Std or HP
Std
Fan Type
Gas or Elec
Gas
C/O Type
w/Heat or w/Cool
w/Cool
2
nd
Stage Heat
Y or N
N
Aux Heat
Y or N
Y
2
nd
Stage Cool
Y or N
N
H/C Delta
3
–
15 deg
3
Heat Delta Stage 1 On
1
– 8
1
Heat Delta Stage 1 Off
0
– 8
0
Heat Delta Stage 2 On
1
– 8
2
Heat Delta Stage 2 Off
0
– 8
0
Heat Delta Stage 3 On
1
– 8
3
Heat Delta Stage 3 Off
0
– 8
0
Cool Delta Stage 1 On
1
– 8
1
Cool Delta Stage 1 Off
0
– 8
0
Cool Delta Stage 2 On
1
– 8
2
Cool Delta Stage 2 Off
0
– 8
0
Max Heat SP
40-
109
F (4-4
2C)
90
F
Min Cool SP
44
-
113
F (
6-
45C)
60
F
Min Run Time
1-
9 min
3
Min Off Time
1-
9 min
5
Temp Response
1-6
2
Fan Cycler Submenu
Fan Cycler ON time
0
–
120
min
0
0 = Fan Cycler
OFF
Fan Cycler Off Time
10
–
120
min
10
Restore Defaults
Yes or No
No
E
xit
= no
USER SETTINGS
Filter Service Submenu
Service Interval
Disabled, 100-4000 hrs
300
Maint Service Submenu
Maint Interval
Disabled, 100-4000 hrs
3000
Scree
n Timeout
(to minimized screen)
0, 20
-120 sec
0
0 = off
, will not timeout
F/C Mode
F or
C
F
Sensor Calibration Submenu
Internal -7 to +7
0
Backlite/Display Submenu
Backli
gh
t Timeout
0, 20
-
120
0
0 = backlite off
Backlight On Brightness
0-
100%
100%
Backlight Off Brightness
0-
100%
0%
Contrast
0-
20
14
1
2
3
4
5
6
7
8
9
Installation Guide
1
Model CH-THSTAT-W
1
Installer Settings screen
4
Installer Settings Summary
7
Heat Pump HVAC System Wiring
9
Comentários a estes Manuais
Sem comentários
Publish
Manuais e produtos relacionados com Termóestatos ClareControls CH-THSTAT-W
Termóestatos ClareControls CH-THSTAT-W Guia do Utilizador
(92 páginas)
Termóestatos ClareControls CH-THSTAT-W Guia do Utilizador
(17 páginas)
Imprimir documento
Imprimir página 7
Comentários a estes Manuais